Easy Touch
Contact Us

Contact Us

Get in touch with us via this contact form or call 1-800-441-9910. Click here for mailing address
Free Demo

Free Tester Demo

Demo any Cirris tester for free! Our 14-day trial gives you the chance find out how we can save you time and money.
 
 
  • Info
  • Specs
  • Options
  • Accessories
  • Adapters
  • Software
  • Documentation

1100 H+

The Signature 1100H+

  • The 1100H+ and add-on boxes support up to 128 test points each; expandable to 1024 points.
  • Combining fast, solid-state, low-voltage continuity scanning with our high-speed hipot algorithm, the 1100H+ is ideal for high- volume testing requirements.
  • Verifies the quality of solder and crimp terminations by checking for high-resistance connections.

Easy to Use

  • Large, easy-to-read LCD screen and user-friendly interface.
  • Easy-to-follow, menu-driven user interface.
  • Test programs generated by self-learning a sample assembly which can be stored in the tester’s non-volatile memory for later use.
  • Different test modes are available to test any type of assembly.

Specifications

Capacity


128 to 1024 points (in 128 point increments)

Test Levels


Low Voltage Tests:

5 volts @ 6mA max current

High Voltage Tests

Insulation Resistance & Dielectric (Hipot) Test: 1500: OFF, 50-1500 VDC ±5% (optional 50-1000 VAC ±5%)

Connection Resistance:

.1 to 100K ohms ± 1% ± .1 ohm, also 500K, 1M, and 5M ohms ±10%

4-wire Resistance:

.001 to 10 ohm ±2% ± .001 ohm

High Voltage Insulation Resistance:

5M, 10M, 20M, 50M, 100M, 200M, 500M, 1000M ohms ±10%

Capacitance:

5nF to 100µF ±10% ± .02nF (10% tolerance)

Connection test:

128 points / .25 second (typical)

High Voltage Dwell (duration):

10 ms to 120 Sec. duration per net

High Speed Hipot:

user selectable, On / Off

Components

Diodes: Silicon, LEDs, Zeners with negative bias breakdown < 4V Resistors: .1 Ohm to 100K Ohm, ± 1% (default tolerance 10%) Capacitors: 5nF to 100uF, ± 10%, ± .02nF (Learn Range is 400nF to 100uF)

Test Rate

Continuity / Low voltage Test: 128 points / .25 second (typical)
Hipot Dwell: 10 ms to 120 Sec. duration per net
High Speed Hipot: user selectable, On / Off

Maximum Capacitance Per net

0.2µF @ 300VDC, 80nF @ 500VDC, 21nF @ 1500VDC

Maximum Points Per Net

100

HV Energy Limit

35 mJoules

Usable Humidity Range

0 to 95% RH (WARNING, I.R. and DWV test results will degrade when Relative Humidity exceeds 75%)

Printer Output

Standard Centronics type parallel interface.

Probe

Accessory for test point identification.

Serial Port:

RS-232 interface. Uses DB9 female connector.

Power Required

100-255VAC, 50-60 Hz., MAX 50W

Dimensions

Main unit: 14.25" x 6.75" x 5.25" (36 x 17 x 13.5 cm)
Add-on: 6.25" x 6.75" x 5.25" (16 x 13.5 x 13.5 cm)

Weight

Main unit: 9.7 lbs. (4.4 kg)
Add-on: 6.3 lbs. (2.8 kg)

Display

4 Line x 20 character LCD

Warranty

One (1) year parts and labor. Replacement modules are generally available next working day.>
PDFDownload 1100 H+ Specs

1100H Tester Options

  • C115-H+ 1100H 1500VDC 128 points

    This 1100H unit has 128 total test points for testing, up to 1500VDC. Note: Buying only the number of points that you need reduces your project cost without sacrificing features you desire.

  • C115-64 1100H 1500VDC 64 points

    This 1100H unit has 64 total test points for testing up to 32 circuits, up to 1500VDC. This tester is ideal for applications with a low point count and suitable for embedding into automated machine applications. Note: Buying only the number of points that you need reduces your project cost without sacrificing features you desire.

  • C120-H+ 1100H 2000VDC 128 points

    This is essentially the same tester as the 1100H 1500VDC, but can apply high voltage from 50- 2000VDC (1000VAC is an optional addition). The 2000VDC version of the tester uses plates to keep the adapters locked into place—it does not use the slide locks that are built into the tester. Note: To fully use voltages between 1500-2000VDC there is only one adapter available that you can use to create mating connectors (Adapter Part# H2KM-64). We also have premade mating cables to help you save time and labor when building your test interface (Cable Part# AC61-KF).

  • C120-64 1100H 2000VDC 64 points

    This 1100H unit has 64 total test points for testing up to 32 circuits. This tester is ideal for applications with a low point count and suitable for embedding into automated machine applications. Note: Buying only the number of points that you need reduces your project cost without sacrificing features you desire. This version can reach out and touch your application that requires up to 2000 VDC to test. It is also great for connector testing.

  • C115-HA 1100H expansion box 128 points

    This item is a 1500VDC expansion box for our 1100H test system. You can order up to 7 expansion boxes to increase the size of your system up to 1024 test points. This option is ideal for testing larger backplane or harness applications. Each box has 128 points and plugs in quickly and efficiently with a cable (included with the box). Please call if you are going to increase your system to the full 1024 test points as we have cabling and mounting options to repackage the physical size. Hint: the two options are Torpedo style or the 4x4 style.

  • C200-HA 1100H 2000VDC 128 points

    This item is an expansion box for our Easy Touch test system. You can order up to 3 expansion boxes to increase the size of your 2000VDC system up to 512 test points allowing you to test larger backplane or harness applications. Boxes can be mixed and matched between voltage levels, but the voltage cannot be greater than the lowest voltage expansion box in the group. Each box has 128 points and plugs in quickly and efficiently with a cable (included with the box).

  • S1KV-AC AC option for 1100H+ (1000VAC)

    This option adds an AC voltage source to the high voltage (hipot) tester of your choice. 1100H+ and 1100H units that are already in the field can be upgraded to include this feature if you need to perform hipot tests that are in AC instead of DC. Call 1-800-441-9910 for details on how to upgrade. We will need your serial number and unit model when you call.

  • SCPT-1H Scripting option for 1100H

    By using scripting you can make the tester extremely flexible and customize a test process to fit a unique task. The following list gives examples for using scripts:

    • Create complex tests that are easy for line workers to use.
    • Make highly customized reports or cable tags.
    • Control external devices such as lamps, hold-down clamps, markers, etc.
    • Test devices such as switches, gas fuses, zener diodes, bi-color diodes, etc.
    • Verify color and lighting of LED’s.
    • Display prompt messages.
    • Hipot different nets at different voltages.
  • LAN-11 Server Software for easy-wire (up to 5 testers)

    This software allows the operation of the Easy Touch, 1100R+ & 1100H+ systems in a client server environment. This server software can be installed on Windows XP (Professional) and Windows 7 (Professional), Windows Server 2003, Windows Server 2008. Cirris Server Software allows centralized management of the single database file to be accessed and used by all test stations. The software provides centralized management of Security Settings, Test Programs, and Test Reports data. You can manage your tester needs from any client connected to the Cirris Server Software. Server and Clients must be running the same version.

  • SLD-LK Slide-Lock Scanner Upgrade

    The Slide-Lock Scanner allows operators to lock adapters in place without using a removable cover plate. Locking slides hold adapters firmly in place to reduce connector wear.

  • SPC-EN Enable SPC Data Collection

    "SPC Data Collection" is an optional feature used on the 1100R+, 1100H+, and Touch1 model cable testers. It is used to collect a wide variety of test data thru your qualified Cirris testers electronically. You are then able to format, print, and extrapolate test data using third party SPC data processing programs or your own spreadsheet. Many of our customers use SPC Data collection to analyze and improve their product quality and to generate reports for either their customers or in-house management team. For more information go to http://www.cirris.com/software/software-options.html

  • LAN-11 Networking option for 1100H+

    Networking Made Easy software enables you to share folders on a Windows based machine with Cirris 1100 series or model Touch1 cable testers. If you are currently using the Touch1 or 1100 series testers and are running around with floppy disks or a thumb drive to add programs or collect SPC data, then this software is for you!

    For more information go to http://www.cirris.com/software/software-options.html

Accessories

PCHK
PCHK-11 Performance Check Kit
Performance Check Kit for the 1100H cable tester.
Red Probe
APRB-BJ Probe
Probe for Signature 5000, 1000LC, Touch1, Easy Touch, CH+ and 1100 series cable testers. (banana jack)
Frame Stand
ACIR-1+ Frame Stand
Helps with interfacing "non-standard" connectors to cable testers. Fits on scanner section of tester where Cover Plates normally attach. This part number fits on models; 1000R+/1000HN/1000H+, 1100-R+/1100-H+, Touch 1 & Easy Touch cable testers.
Adjustable Tilt Stand
ATLT-NA Non-Adjustable Tilt Stand
Non-Adjustable Tilt Stand for testers: 1000M / 2000 / 1100R+ /1100H+ / Touch1 & Easy Touch models
Adjustable Tilt Stand
RPWR-11 Replacement power cord for the 1100 series cable testers.

Adapters

.1" Dual Row Connectors


AHED Adpaters

AHED-26 Adapter
  • Number of Positions:...... 10, 14, 16, 20, 24, 26, 30, 34, 40, 44, 50, 60, 64.
  • Adapter Gender:....MALE
  • Keyed?:....Center Key
  • 1500V Option Available?:....(64 pos. only)
  • Replaceable Option Available?:....YES
  • Testable Grounded Shell Available?:....NO
  • Pin Count Format:....Alternating or Staggered

AHEF Adpaters

AHEF-26 Adapter
  • Number of Positions:...... 10, 14, 16, 20, 24, 26, 30, 34, 40, 44, 50, 60, 64.
  • Adapter Gender:....FEMALE
  • Keyed?:....None
  • 1500V Option Available?:....NO
  • Replaceable Option Available?:....NO
  • Testable Grounded Shell Available?:....NO
  • Pin Count Format:....Alternating or Staggered

.050" Dual Row Connectors


AH50 Adpaters

ah50
  • Number of Positions:...... 10, 20, 30, 40, 50, 60, 80, 100, 120.
  • Adapter Gender:....Male
  • Keyed?:....Center Key
  • 1500V Option Available?:....NO
  • Replaceable Option Available?:....NO
  • Testable Grounded Shell Available?:....NO
  • Pin Count Format:....Alternating or Staggered

Dsub


ADBP Adpaters

ADBP-15 Adapter
  • Number of Positions:...... 09, 15, 25, 37, 50.
  • Adapter Gender:....Female
  • 1500V Option Available?:....YES
  • Replaceable Option Available?:....YES
  • Testable Grounded Shell Available?:....YES
  • Pin Count Format:....Column Count
ADBS-25 Adapter
  • Number of Positions:...... 09, 15, 25, 37, 50.
  • Adapter Gender:....Male
  • 1500V Option Available?:....YES
  • Replaceable Option Available?:....YES
  • Testable Grounded Shell Available?:....YES
  • Pin Count Format:....Column Count

Ribbon Connectors .085"


ABRM Adapters

ABRM-24 Adapter
  • Number of Sockets:...... 14, 24, 36, 50, 64 Pos.
  • Adapter Gender:....Female
  • 1500V Option Available?:....(50 pos.only)
  • Replaceable Option Available?:....YES
  • Testable Grounded Shell Available?:....YES
  • Pin Count Format:....Column Count

ABRF Adapters

ABRF-36 Adapter
  • Number of Positions:...... 14, 24, 36, 50, 64 Pos.
  • Adapter Gender:....Male
  • 1500V Option Available?:....(50 pos.only)
  • Replaceable Option Available?:....YES
  • Testable Grounded Shell Available?:....YES
  • Pin Count Format:....Column Count

Shielded .050 "D" Type


AD5P Adapters

AD5P-40 Adapter
  • Number of Positions:...... 20, 26, 40, 50, 60, 68, 80, 96, 100, 120.
  • Adapter Gender:....Female
  • 1500V Option Available?:....NO
  • Replaceable Option Available?:....YES
  • Testable Grounded Shell Available?:....Standard
  • Pin Count Format:....Column Count

AD5S Adapters

AD5S-68 Adapter
  • Number of Positions:...... 20, 26, 40, 50, 60, 68, 80, 96, 100, 120.
  • Adapter Gender:....Male
  • 1500V Option Available?:....NO
  • Replaceable Option Available?:....YES
  • Testable Grounded Shell Available?:....Standard
  • Pin Count Format:....Column Count

Micro D Connectors


AMDP Adapters

AMDP-15 Adapter
  • Number of Positions:...... 15, 26, 44, 62, 78.
  • Adapter Gender:....Female
  • 1500V Option Available?:....(Call for availability)
  • Replaceable Option Available?:....YES
  • Testable Grounded Shell Available?:....YES
  • Pin Count Format:....Column Count

AMDS Adapters

AMDS-26 Adapter
  • Number of Positions:...... 15, 26, 44, 62, 78.
  • Adapter Gender:....Male
  • 1500V Option Available?:....(Call for availability)
  • Replaceable Option Available?:....YES
  • Testable Grounded Shell Available?:....YES
  • Pin Count Format:....Column Count

Card-edge Adapters


ACEF Adapters

ACEF-20 Adapter
  • Number of Positions:...... 10, 20, 26, 30, 34, 36, 40, 44, 50, 60, 64. position.
  • Adapter Gender:....Male
  • Keyed?:....Standard (between positions 3 & 5)
  • 1500V Option Available?:....NO
  • Replaceable Option Available?:....NO
  • Testable Grounded Shell Available?:....NO
  • Pin Count Format:....Alternating or Staggered

Modular Phone Plugs


AMJK Adapters

AMJK-SP Adapter
  • Number of Positions:...... 4, 6, 8, position. (10 position custom)
  • Adapter Gender:....Female
  • Keyed?:....Center Key, (As in Photo)
  • 1500V Option Available?:....NO
  • Replaceable Option Available?:....YES
  • Testable Grounded Shell Available?:....In some cases.
  • Pin Count Format:....N/A

Single Row Headers


ASIL-SS Adapter
  • Number of Positions:......
    ASIL-SS has 1 - 12 positions
    ASIL-SD has 1 - 24 positions
    AHDS-SS has 1 - 14 positions
    AHDS-SD has 1 - 30 positions
  • Adapter Gender:....Male
  • 1500V Option Available?:....NO
  • Replaceable Option Available?:....NO
  • Testable Grounded Shell Available?:....NO
  • Pin Count Format:....Column

.8mm


A8MM Adapters

A8MM-36 Adapter
  • Number of Positions:...... 36, 50, 68
  • Adapter Gender:....Female
  • 1500V Option Available?:....NO
  • Replaceable Option Available?:....YES
  • Testable Grounded Shell Available?:....Standard.
  • Pin Count Format:....Column Count

2mm Single or Dual Row Connectors (shrouded and un-shroudedThis is the content for Layout Div Tag "twomm"


AH2M Adapters

AH2M-SD Adapter
  • Number of Positions:......2 through 100 positions (Unshrouded)
  • Number of Positions:......40, 44 and 50 Positions (Shrouded)
  • Adapter Gender:....Male
  • 1500V Option Available?:....NO
  • Replaceable Option Available?:....NO
  • Testable Grounded Shell Available?:....NO
  • Pin Count Format:....Alternating or Staggered

Eurocard Connectors


AVM2 Adapters

AVM2-32 Adapter
  • Number of Positions:......32, 64, 96
  • Adapter Gender:....Male
  • 1500V Option Available?:....(only on AVM2-64)
  • Replaceable Option Available?:....NO
  • Testable Grounded Shell Available?:....NO
  • Pin Count Format:....Column Count (A & B)

Rack and Panel Connectors (V.35)


AVDS Adapters

AVDS-34 Adapter
  • Number of Positions:......34 positions
  • Adapter Gender:....Male
  • 1500V Option Available?:....NO
  • Replaceable Option Available?:....NO
  • Testable Grounded Shell Available?:....NO
  • Pin Count Format:....N/A

AVDP Adapters

AVDP-34 Adapter
  • Number of Positions:......34 positions
  • Adapter Gender:....Female
  • 1500V Option Available?:....NO
  • Replaceable Option Available?:....NO
  • Testable Grounded Shell Available?:....NO
  • Pin Count Format:....N/A

USB and Firewire Adapters


USB Adapter

AUSB-4B Adapter
  • Number of Positions:......4 positions
  • Adapter Gender:....Male
  • 1500V Option Available?:....NO
  • Replaceable Option Available?:....NO
  • Testable Grounded Shell Available?:....Standard
  • Pin Count Format:....N/A

Fire Wire Adapter

AFWR-06 Adapter
  • Number of Positions:......6 positions
  • Adapter Gender:....Male
  • 1500V Option Available?:....NO
  • Replaceable Option Available?:....NO
  • Testable Grounded Shell Available?:....Standard
  • Pin Count Format:....N/A

LFH Connectors


ALFH Adapters

ALFH-60 Adapter
  • Number of Positions:......60, 160, 200 positions
  • Adapter Gender:....Female
  • 1500V Option Available?:....NO
  • Replaceable Option Available?:....NO
  • Testable Grounded Shell Available?:....Standard
  • Pin Count Format:....Continuous

Circular Mini Dins


AMDN ADapters

AMDN-06 Adapter
  • Number of Positions:......3, 4, 5, 6, 7, 8 positions
  • Adapter Gender:....Female
  • 1500V Option Available?:....NO
  • Replaceable Option Available?:....NO
  • Testable Grounded Shell Available?:....Standard
  • Pin Count Format:....N/A

Coaxial Connectors


ABNC Adapters

ABNC-02 Adapter
  • Number of Positions:......2 positions
  • 1500V Option Available?:....NO
  • Replaceable Option Available?:....NO
  • Testable Grounded Shell Available?:....Standard
  • Pin Count Format:....N/A

Discrete Connectors


ADIS Adapters

ADIS-20 Adapter
  • Number of Positions:......4 thru 20 positions(4 position increments)
  • Adapter Gender:....Female
  • 1500V Option Available?:....NO
  • Replaceable Option Available?:....NO
  • Testable Grounded Shell Available?:....NO
  • Pin Count Format:....standard column count

PCB Transition Connectors


APCD Adapters

APCU-60 Adapter
  • Number of Positions:......50, 60, 68-120 positions
  • Adapter Gender:....FEMALE (uses spring-loaded pins)
  • 1500V Option Available?:....NO
  • Replaceable Option Available?:....N/A
  • Testable Grounded Shell Available?:....N/A
  • Pin Count Format:....

VME Connectors


A1KM-64 Adapter
  • Number of Positions:......2 x 64 positions
  • Adapter Gender:....FEMALE
  • 1500V Option Available?:....Standard
  • Replaceable Option Available?:....NO
  • Testable Grounded Shell Available?:....NO
  • Pin Count Format:....custom, (Alternating or Staggered) with center row missing and every other pin missing.

Easy Touch Software:

1100H Current Software Version: 5.3c

(Where do you locate the machine version number on the 1100H? Main menu display, down arrow once, select "Version Information" displays vers. info.)
WARNING: Before upgrading to a new software version, always BACK-UP your existing test files and your existing database file!


Current Software Download Firmware Version: 5.3c
PLEASE NOTE: This software updates both the 1100-R+ and the 1100-H+ models. To understand the download and install sequence please read this Readme File.
Download 5.3c
1100 USB Version 2.29 Updating Software
Download 2.29 version

New Utilities Software which includes Security Explorer
Download 2009.3.0.5650 utilities Software

Download Readme File for utilities software

Easy Touch Station Software


This software allows any 1100-H+ testers to be controlled by a Windows PC for all learning, testing, and editing functions. It essentially can turn any existing 1100H+ tester into an Easy-Touch tester. Measured Values, Custom Reports, Network printing, and much more.
Download 2012.4.3
2012.4.3 Read me
PLEASE NOTE: There is a fee associated with upgrading your software. Most software .EXE files are zipped with password protection! Call your Cirris sales representative with your PO or Credit Card information to receive the passcode for your selected software. Call toll free at 1-800-441-9910.

Cirris Server Software for Models Easy Touch, 1100R+, 1100H+. Vers 2011.3

(August 25, 2011)
This software allows the operation of the Easy Touch, 1100R+ & 1100H+ systems in a client server environment. This server software can be installed on Windows XP (Professional) and Windows 7 (Professional), Windows Server 2003, Windows Server 2008. Cirris Server Software allows centralized management of the single database file to be accessed and used by all test stations. The software provides centralized management of Security Settings, Test Programs, and Test Reports data. You can manage your tester needs from any client connected to the Cirris Server Software. Server and Clients must be running the same version.
PLEASE NOTE: There is a fee associated with upgrading your software. Most software .EXE files are zipped with password protection! Call your Cirris sales representative with your PO or Credit Card information to receive the passcode for your selected software. Call toll free at 1-800-441-9910.
Download Vers. 2011.4.0.2950 Cirris Server Software


Networking Made Easy (Version 2011.1.0.3800 Dec 2010)


Software is used to network Touch 1, 1100-R+, 1100-H+ model testers which have the networking option installed. This software allows you to read and write test programs and data files to a shared network drive. Must be installed on either Windows XP, Windows 7, Server 2003 or 2008 Operating systems. Touch1 and 1100 tester firmware must be a version greater than 4.9.
Download Networking Made Easy Version 2011.1.0.3800
PLEASE NOTE: There is a fee associated with upgrading your software. Most software .EXE files are zipped with password protection! Call your Cirris sales representative with your PO or Credit Card information to receive the passcode for your selected software. Call toll free at 1-800-441-9910.

1100H+ Documentation

PDF
This getting started guide walks you through how to set up and operate the 1100H hardware and software. An overview is included on how to learn, verify, and test a sample cable.
Download 1100H+ Getting Started Guide

1100 H+ Performance Verification Kit


PDF
The 1100H+ Performance Verification Kit allows you to verify the calibration and proper operation of the 1100H+ tester.


Download 1100H+ Performance Check Kit

Easy Touch scripting Manual


PDF
You can use Easy Touch scripting on a Cirris Easy Touch tester or on a Cirris 1100 tester that is controlled by a PC running the Cirris easy-wire software. An Easy Touch script will typically not run on an independent 1100 Tester, or on a Cirris Touch1 tester. A Cirris scripting language with some different commands is used for these applications.


Download Easy Touch Scripting Manual
PDF1100 H+ Brochure
PDFDownload 1100 H+ Specs
PDFDownload 1100 H+ Quick Reference Guide
PDFDownload 1100 Basic use of the SPC feature
PDFBasice use of CTLWIN Software



1100H Demo Video