Cable Testers and Harness Testers Made Easy! | |
| Capacity | Expandable from 160 to 20,000 points in 160 -point increments |
| Continuity Test - 2 wire: | Voltage: standard 2.5 volts Current: 1uA to 10mA Resistance: 0.1 ohm to 1M ohm ±2% ±0.1 ohm |
| Continuity Test - 4 wire: | Voltage: standard 2.5 volts Current: (.001 ohm - 1 ohm)-2A (1 ohm - 10 ohm)-200mA (10 ohm - 100 ohm) -20mA Resistance: .001 ohm to 100 ohm ±2% ±0.001 ohm Capacitance: 1pF to 1000µF ±10% ±50pF; |
| Insulation Test: | Voltage: 100 to 1500VDC or 100 to 1000VAC (50 Volt steps) ±5% ±5V Resistance: 5M ohm to 1000M ohm ±10% |
| Dielectric Withstand Test: | Voltage: 100 to 1500VDC or 100 to 1000VAC (50 Volt steps) ±5% ±5V Current Limit: (DC) 0.1mA to 2.5mA (AC) 0.1mA to 1.5mA (RMS) Dwell: (DC) 10ms to 120 sec. (AC) 17ms to 120 sec. (1 to 7200 cycles) Test Rate: 256 points per second or faster (typical) |
| Max Capacitance Per Net: | 15nF @ 1500VDC, 2.5nF @ 1000VAC |
| HV Energy Limit: | 35 mJoules |
| Digital Input/Output | 8 Inputs / 8 Outputs, 30V Open collector, T1 compatible. +12V and +5V each current limited to 500mA |
| Hot Plugging | Scanner nodes and base units will survive hot plugging between boxes and between stacks of boxes. |
| External Relay Actuation | 160 to 800 points - in 160 point increments (requires optional relay energization hardware). |
| Test Point Connector | 96 pos. FEMALE VME Eurocard connector-32 pos. loaded |
| Computer Requirements | CPU Speed: 1.6 GHz or faster, OS: Windows 2000 or XP(recommended), Disk Space: 5GB(min) 10G(recommended),
RAM: 512M (min) 1G (recommended), Video Memory: 64 Meg RAM, USB Ports: 1 USB (min) 2 USB (recommended) (2.0 Compatible), CD-ROM Drive and Sound card are required. Serial Port: 1 port, Display resolution: 1024 X 768 or better. Server Requirements: Operating System: Windows 2000 or 2003 Server. RAM: 1Gig. Disk Space: 10G (min). |
| Disbributed Test | Maximum distance from Base unit: 200 ft. |
| Power | 105-135VAC, 60 Hz. 60 Watts (210-260VAC 50 Hz. optional) |
| Probe Connector | 1 per scanner node - 2 RS-422, 1 test point, ±12V @ 100mA power. |
| Size (each box) | 6.125" tall x 17" wide x 17" deep (16 x 42 x 42 cm) |
| Weight (each box) | 20 lbs. (9 kg) |
| Temperature | Specified: Operational 10 to 40 degrees C; Storage -40 to 70 degrees C |
| Humidity | 0 to 95% RH (WARNING, I.R. and DWV test results will degrade when Relative Humidity exceeds 75%) |
| Warranty | One year parts and labor. Replacement modules available next working day. |
© Cirris Systems Corp.