  • Scanner chassis measures 17" x 17" x 6" and weighs 40 lbs.
  • Up to five 160 point scanner boxes (800 pts/box)
  • Tests up to 100,000 points
  • 1500 VDC
  • 1000 VAC
  • Easily rack mounted for larger applications
  • Performance Check Kit for ISO 9000 certification

Software

  • easy-wire software provides full SPC data collection
  • Collect test results by operator, test station, or product
  • Customize any standard test report
  • Password-protected security
  • Limit operator access to system features.
  • Online help system

Efficient and Adjustable

  • Smart-Lights capable
  • Zero Defect Guided Assembly Aid
  • Built in digital I/O
  • 8 programmable inputs and 8 outputs
    • Marking/stamping machines
    • Fixture locks
    • Pushback modules
    • Energizing relays

 

Test Points

160 to 800 points; expandable to 100,000 points in 160-point increments. (Max distance from base unit: 200 ft.)

Low Voltage Test

2 Wire

  • Voltage: Standard 2.5 V max
  • Current: 10 mA to 1 μA
  • Resistance: 0.1 Ω to 1 MΩ ±2% ±0.1 Ω

4 Wire

  • Voltage: Standard 2.5 V max
  • Current: 2 μA to 2 A
  • Resistance: .001 Ω to 100 Ω ±2% ±0.001 Ω

Components Test

  • Diodes: 0 to 2.5 V
  • Resistors: 0.1 Ω to 1 MΩ ±2%
  • Capacitors: 10 pF to 5000 μF ±10% ±50 pF
  • Twisted Pairs: Verify proper pairing in twisted pair cables

High Voltage Test

Insulation Resistance Test

  • Voltage: 10 to 1500VDC ± 5% ± 5 V
  • Resistance: 5 MΩ to 1000 MΩ ±10%

Dielectric Withstand Test

  • Voltage: 10 to 1500 VDC ± 5% ± 5 V or 10 to 1070 VAC ± 5% ± 5 V (up to 1500 VAC with xHV option) (1 volt steps)
  • Current Limit: (DC) 10 μA to 2.5 mA, (AC) 10 μA to 2.5 mA (RMS) or to 22 mA with xHV option
  • Max Capacitance Per Net: 30 nF @ 1500 VDC, 9.5 nF @ 1000 VAC
  • HV Energy Limit: 35 mJ
  • HV Charge Limit: 45μC

Max Points Per Net

Unlimited

Digital Input/Output

8 Inputs / 8 Outputs, 30 V Open collector, +12 V and +5 V each current limited to 100 mA

Test Point Interface

96 pos. Female VME Eurocard connector-32 pos. loaded

User Interface

PC Requirements

  • Test Station: 2.0 GHz min. processor speed, Windows 7®, or Windows 8.1®, 15 GB hard drive space, 4 GB RAM, 256 MB min. video memory, 1024 x 768 min display resolution, sound (for audible feedback), USB 2.0 or 3.0 port
  • Optional Network Database Server: As above except no sound or USB ports required. Windows XP®, Windows 7®, Windows 8.1®, Windows Server 2003® or Windows Server 2008® OS

Power

115 / 230 V 50/60 Hz

Size

17” x 17” x 6” (43cm x 43cm x 15cm) (base or expansion enclosure)

Weight

40 lbs (18kg) (fully loaded base or expansion enclosure)

 

CH2 XHV - 1500VAC Test System

CH2 XHV 1500VAC Test System

  • Set a DWV current leakage threshold of up to 5mA (real) and 22mA (total)
  • Up to 1500VAC
  • Test assemblies with higher capacitance
  • Test much longer cables

Test Levels

  • Output Voltage:10 to 1500 VAC ±5% ±5V
  • Voltage Resolution:1 VAC
  • Total Current Limit:10µA to 22mA ±10% ±10µA
  • Real Current Limit:10µA to 5mA ±10% ±10µA

Test Rate

  • Dwell Time:17 ms to 120 sec. (1 to 7200 cycles @ 60 Hz) (1 to 6000 cycles @ 50 Hz)
  • Output Waveform:Sine wave
  • Output Frequency:50 or 60 Hz
  • Voltage Ramp Up Time:0 to 120 seconds
  • Voltage Ramp Down Time:0 to 120 seconds

Other Requirements

  • Power:100-240VAC, 50 to 60 Hz. 80 Watts
  • Temperature:Specified:10-40 degrees C, Operational: 0-70 degrees C
  • Humidity:Specified:0-50% RH non-condensing, Operational: 0-90% RH non-condensing

Dimensions

  • 3.5" tall x 17" wide x 19.75" deep (9x 43 x 50 cm)

Weight

  • 28 lbs. (13 kg) (each box)

CH2 - Energization Box

CH2 Energization Box

  • Energize lamps, LEDs, relays or other devices needing external power
  • Connected to a CH2 test system using the same cable as a standard expansion box
  • Design your test to accommodate a wide variety of external power needs using easy-wire software
  • Power supply port on the back of the box to plug in your selected power supply
  • Optional Programmable Power Supply
  • adjust voltages to multiple values within one test program
  • Additional information:
  • Energization Specifications:
    • Energization Points: 160 - 800 Points (in 160 pt. increments)
    • Max Current: 2 AMPs
    • Fixed Voltage Supplies: 5, 12, 15, 24, 28, & 48 Volts
    • Agilent Variable Supply: 0 to 60 Volts
    • Interfacing to E-Unit: Standard AC61-KF cabling

CH2 Custom Instructions

Agilent 34410A

  • add-in set of test instructions to expand the capability of the tester
  • integrate external meters, such as a Keithley 24xx series source meters or Agilent 344xx series DMMs to make high accuracy measurements using those instruments
  • integrate a variable power supply when using the Energization Module
  • different voltages for different applications in the same test program
  • Test: Transzorbs, Zener Diodes, Gas Discharge Tubes etc.
  • Test Relays: Single Coil, Multi Coil, Pull-in-voltages, Drop-out-voltages etc.
  • Test Light/Indicators: Single Lamp to 60V, Multi Lamps up to 60V
  • Test Leakage Current: Diodes, Transistors, MOSFET's, Integrated Circuits, etc.
  • Highly Accurate Voltage or Current Measurements: With integrated Keithley 2400 series meter

CH2 Adapter Panel System

CH2 Adapter Panel

  • Adapter panel mounts directly to the front of the CH2 tester
  • adapt from the 32 pin Eurodin style connectors to mating connectors of your choice

Performance Verfication

  • The CH2 Performance Check Kit allows you to verify the calibration and proper operation of the CH2 tester. 
  • For information on tester calibration, click here.

CH2 Version Lookup

On the main menu screen of easy-wire, the verson number is located on the mid-right side of the window.

The following software products are available for the CH2:

Cirris easy-wire Software

Cirris Server Software

LUA Scripting

Basic Information

 

Additional Information

Ask About This Product

OR Contact Your U.S. Sales Rep

Select your state to view the contact information of your regional representative.

 

 

 

OR Contact Your International Distributor

Select your country to view the contact information of your Cirris distributor. If your country is not listed, Please complete the preceding form.