A Revolutionary Approach for Pinning a Connector.
When building harnesses or cables that use individually labeled discrete wires, it is not good enough to make sure that the harness is electrically correct! You must also insure that each labeled wire is inserted into the correct cavity of the connector. This is especially critical when building single-ended harnesses that get second-end termination in a cabinet or in the field. This type of harness building requires the assembly person to correctly identify each wire and install it in the proper location in the connector. Cirris has recently pioneered the development of hardware and software that goes a long way to insure that labeled wires are inserted into the proper locations in the connector.
Contact Retention Monitor:
In addition to helping the operator accurately insert each wire in the correct cavity of the connector, Pin-Sight monitors the insertion force and gives a warning tone if excessive force is used. Pull-back force is set to give the operator a tone to verify that the contact is locked in, and also gives a warning tone if excessive pull-back force is used.
|