Tensile Strengths (lbs)

 

Gauge SAE AS7928
Table II
MIL-T-7928G
(for ref.)
U.L. 486A
Terminals
U.L. 486C
Splices
DIN
41611/3
NASA-STD
8739.4
32 1.4
30 2.1
28 3.2 5
26 7 7 3 3 5.0 8
24 10 10 5 5 8.1 8
22 15 15 8 8 11.1 13
20 19 19 13 10 17.1 21
18 38 38 20 10 25.2 32
16 50 50 30 15 39.8 41
14 70 70 50 25 58.0 65
12 110 110 70 35 92.1 103